Fixtures, bulbs, timers, and dimmers to custom brighten your days.
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 1/2 in thick steel wraparound mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Eaton's Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCIs provide state-of-the-art, dependable electrical shock protection. In addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power.
Standard duplex receptacles feature longer, wider straps providing 40% more contact area to the wallboard. Virtually eliminates floating installations. Patented built-in wire stripper for #14 and #12 wire to speed installation. Patented built-in wire looper for pre-looping. Tri-combo screws accept slotted, Phillips and Robertson-head tools for installation flexibility. Terminal screws backed out - ready for wiring. Side wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire.
Ultrasonic welding and integrated construction of the strap and body. Backwire clamps on the side terminals for installation of #12 and #14 wire. Redesigned paddle. Built-in wire stripper for #12 and #14 wire. Stippled ground screw standard. 120/277 VAC rating for fluorescent lighting fixtures typical in commercial applications. Push in terminals accept #14 solid wire only. Temperature rating of -20 to 60 deg C. Meets flammability requirements per UL 94, 6504, V2 rated, VO rated. UL and cUL Listed, Meets all UL20 requirements, file # E18704. Carded.
For use whenever weatherproof protection is required for an "on/off" type switch. Powder coat finish. Supplied with a switch unassembled to the cover - no need to purchase separate components. Includes installation hardware and multi-lingual instructions. Size 4-1/2 in L x 2-3/4 in W. UL listed, CSA, NEMA 3R Rated.
For outdoor horizontal use. Powder coat finish. Scratch-resistant. Self-closing lid assures protection when receptacle is not in use. Includes installation hardware, gasket and multi-lingual instructions. UL 514-A listed, File E 195978 C/UL CSA C22.2 No. 18 NEMA 3R rated.
Horizontal device mount. Weatherproof covers for protection of outdoor receptacles. State-of-the-art powder coat finish provides maximum weatherability and scratch resistance. Self-closing lids assure weatherproof protection when the receptacle is not in use. Includes installation hardware, gasket and multi-lingual instructions. Size: 4-1/2 in x 2-3/4 in. UL 514-A listed, File E195978 CSA C22.2 No. 18 NEMA 3R Rated.
TAYMAC Weatherproof Cover, Aluminum, Gray, 4-9/16 in Length, 2-13/16 in Width, 3R NEMA Rating, Horizontal Mounting, Includes: Gasket, Installation Hardware
Impact resistant thermoplastic housing with finger grip grooves. Plug blades are firmly embedded in body. Polarized. NEMA 1-15, UL listed. Carded.
Impact resistant thermoplastic housing with finger grip grooves. Plug blades are firmly embedded in body. Polarized. NEMA 1-15, UL listed. Carded.
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. UL listed E35297.
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. SCH 40. UL 651 Listed to the NEC by the ETL, UL listed.
Offers same chemical resistance as carbon non-metallic conduit for a complete, corrosion-resistant system. UV-resistant for use in direct sunlight. Use in accordance with conduit spacing requirements per NEC. Each clamp requires 2 screws, 2 nuts and 2 washers. Gray clamps for standard conduit.
Carlon Standard Coupling, 2 in Trade, PVC, Gray, 2-1/2 in Length, 2.19 in ID x 2.734 in OD Diameter, Suitable for: SCH 40 and 80 Conduits